WUFI® Passive

800x321_WUFI-Passive-Schaubild
800x321_WUFI-Passive-3D-Wärmebrücke
800x321_WUFI-Passive-Multizonenmodell

WUFI® Passive allows a double assessment of buildings based on the same building model:

  • A monthly energy balance method is used for the design and verification of buildings meeting the passive house criteria following EN 13790
  • The dynamic building simulation of WUFI® Plus is used for the detailed dynamic assessment of the hygrothermal behavior of buildings meeting the passive house criteria, as well as individual components.

Combining monthly balance and the dynamic method allows designers to optimize passive buildings for local climate conditions while maintaining indoor comfort.

Passive houses are characterized by extremely low energy consumption. Dynamic hygrothermal models are necessary to accurately model the hygrothermal behavior of buildings in dynamically changing climates or climates where cooling and dehumidification of the indoor air play an important role. Thermal and hygric inertia can be considered in detail to further reduce energy demand and to eliminate limitations in indoor comfort (overheating, for example).

In many climate zones, the use of highly insulated components presents risks—such as moisture issues, for example—to designers and construction professionals. Managing this risk requires a dynamic hygrothermal assessment under real climatic conditions.

To meet this need, the Fraunhofer-Institute for Building Physics (IBP) and Passive House Institute US (PHIUS) developed WUFI® Passive combining the WUFI® Plus building simulation tool with the PHIUS+ passive house verification criteria.


60x50_Zielgruppen
Targeted audience

Designers

Zielgruppe Planer

Passive House Verification:

Passive House design and verification according to PHIUS

Calculation of heating/ cooling energy demand, heating/ cooling load

Design of components and HVAC-system

Calculation of primary energy demand/ electric power consumption/ hot water consumption

Design of ventilation and shading

After meeting Passive House Standard:

Calculation of the heating and/or cooling demand

Hygrothermal design of structural components

Simulation and comfort rating of the indoor climate

System sizing technique

Analysis of thermal bridges

Consultants

Zielgruppe Gutachter

Locating vulnerabilities in the building envelope

Damage investigations

Proofing ventilation and shading design

After meeting Passive House Standard:

Mold growth assessements

Building Products Companies

Zielgruppe Baustoffhersteller

Determination of the required product characteristics

Assessment and comparison of individual components in a system

Suitability of materials and components for Passive Houses

Suitability of HVAC-systems for Passive Houses

After meeting Passive House Standard:

Evaluation of the influence of individual components on the indoor climate and energy consumption

Construction companies & housing companies

Zielgruppe Baufirmen

Drying of construction moisture and/or water damage

Ensuring the quality of a building’s energy performance

Avoiding poor performance and/or damage caused by the building design (e.g., summer overheating, mold, etc. …)

Universities and Technical Colleges

There are special conditions for using WUFI® Plus for educational purposes. Additional information can be found here.

* Upon evaluating damage in existing structures, if the simulation correctly accounts for uncertainty (e.g., driving rain, leaks in ETICS, and/or convective moisture entry with lightweight components) and does not predict damage, then the workmanship is to blame. On the other hand, if the simulation predicts that damage can occur, then poor design is to blame.


Zahnrad

Application

Passive house designDynamic simulationThermal control
Fragezeichen

Typical questions

  • Passive house design and certification
  • Investigation of passive design strategies such as building orientation and geometry, shading, solar gains with sun protection, the use of thermal mass, and ground connections
Ausrufezeichen

Results

  • General results include heating/cooling demand, heating/cooling load, and primary energy demand
  • Detailed analyses include energy balance, heat flux, power consumption, heat fluxes in individual components, ventilation, systems engineering, appliances, hot water (consumption/distribution), and shading
  • MSWord export of a comprehensive passive house certification report with a detailed description of all results, extensive graphs, and complete project documentation
Fragezeichen

Typical questions

  • Indoor climate, thermal comfort, and energy consumption calculations
  • Hygrothermal component evaluation under use-dependent, dynamic climate conditions
  • Implementation of energy-efficient ventilation to prevent moisture damage and mold growth
  • Strategies to reduce overheating in summer (see also below)
  • Influence of thermal and hygric storage masses on building energy consumption and indoor climate
  • Hygrothermal building and component behavior in all situation from extreme to intermittent use
  • The influence on energy demand of the need to dry construction moisture and/or moisture damage.
  • Ensuring damage-free building components when usage conditions change and/or renovation takes place.
Ausrufezeichen

Results

  • For each zone in the building:
    • Dynamic climate (temperature, humidity, and CO2 content),
    • Heating and cooling energy demand,
    • Humidification and dehumidification load
    • Dynamic heat and moisture flows (solar, internal, ventilation, windows, and components),
    • Air flow rates (natural, mechanical, and interzonal), and
    • Comfort indices (Predicted Mean Vote (PMV), operational temperature, etc …)
  • For each component and each orientation, the temporal and spatial distribution of the hygrothermal conditions (temperature, relative humidity, and water content) saved as a WUFI® movie
  • All component, zone, and plant engineering results in predefined format and/or as user-defined graphics
  • MSExcel or text export of all dynamic component, zone, and plant engineering results
  • MSWord export of predefined and/or user-defined output reports with complete project documentation and summaries of results
Fragezeichen

Typical questions

  • Proof of summer thermal protection as required by DIN 4108-2
  • Determining the influence of thermal mass on the building response in summer months
  • Analyzing the influence of building geometry and shading on preventing summer overheating
  • Investigating the influence of windows and window properties, fixed sun protection, and shading control
  • Analyzing land-use strategies and ventilation strategies for preventing summer overheating
Ausrufezeichen

Results

  • Full report with over-temperature degree hours for each simulated zone in the building
  • Hourly temperature gradients for each zone
  • Histogram and table of operational temperature frequency
  • Graphical presentation of the excess temperature degree hours per day and average daily temperature variation per month
  • Detailed energy balance showing all heat flows, including breakdowns for all opaque and transparent components

The evaluation of results is the responsiblity of the user and not of the software. Assessing results requires experience and understanding of building science. It is recommended that all users attend a seminar dedicated to WUFI® Pro. The seminars educate users about basic building physics and give confidence for handling the software. In addition, such seminars provide information on new models and evaluation options.


Programmdetails

Program details

The WUFI®-Wiki provides demo movies, guides and tutorials, and information on the theoretical background for WUFI®.

WUFI® Passive simulations require more inputs than WUFI Pro, including detailed building envelope data and information on internal loads, set points, ventilation, and mechanical systems. Building geometry input is supported by a built-in Building Wizard, or by geometry import from SketchUp® or gbXML (e.g., from Revit®). The user can custom-enter realistic daily usage and mechanical systems profiles through the user interface, or the user can employ built-in databases that store standard schedules, internal loads, and engineering system components.

In WUFI® Passive, the user can choose between SI and US-IP units for data input, computation, and output of results. The WUFI® Passive user interface itself can be switched between the following languages: German, English, Polish, and Italian. The online help is in English.

 

Last Update: April 16, 2019 at 11:09