Information on the planned release of WUFI® Pro 6

150x105_News_Pro-6-ReleaseIn spring 2016 we will release the new version of our hygrothermal simulation software WUFI® Pro 6. The most important new features and improvements include:

 

  • New, more stable and faster kernel
  • New climate menu which allows to pick the location from the globe, additional analysis of the climate files and possibility to plot courses of all climatic elements contained
  • New database for custom climates which can be made accessible also on the map
  • New interface for the material database with tree structure, comfortable search function and new possibilities to manage the user data!
  • WUFI® Graph for evaluation of the results allows a direct comparison of different cases within the same diagram, the comparison of 1D and 2D simulation results and the evaluation of average conditions over several grid elements – also for the relative humidity. This also allows for an evaluation of timber structures according to the new WTA guideline 6-8 with its requirements for transient wood decay evaluation.
Contine reading

WUFI® Plus and WUFI® Passive update

The new versions WUFI® Plus 3.0.3 and WUFI® Passive 3.0.3 have been released. Please find an overview of alterations and setup instructions in the update overview.

Free-of-charge updates are listed on the WUFI® online shop in the section „my orders“. The displayed link allows you to download the respective latest version which can be update to for free. Please extract the file and install the software using your existing licence number (usually identified automatically). Earlier versions don’t have to be uninstalled. Chargeable upgrades will be displayed at the online shop when you log in with your WUFI® account.

Find answers in our new FAQ section

FAQ

The FAQ section provides numerous answers to our most frequently asked questions – especially those relating to purchasing and getting started with WUFI®. There you will find, for example, extensive information on what WUFI® programs and licenses are available, what databases they use, how to purchase and pay for the software, and what the system requirements are.

If you already use WUFI® and have specific questions about the software, there are a number of help sources available, such as instruction manuals, tutorials, and the WUFI® forum. An overview of these sources can be found under support. Contine reading

Now available: WUFI® Plus and WUFI® Passive update

The new versions WUFI® Plus 3.0.1 and WUFI® Passive 3.0.1 have now been released. Please find an overview of alterations and setup instructions in the update overview. 

Free-of-charge updates are listed on the WUFI® online shop in the section „my orders“. The displayed link allows you to download the respective latest version which can be update to for free. Please extract the file and install the software using your existing licence number (usually identified automatically). Earlier versions don’t have to be uninstalled. Chargeable upgrades will be displayed at the online shop when you log in with your WUFI® account.

Contine reading

20 years of WUFI® – 20% sale at the WUFI® online shop

150x150_WUFI_20-Years20 years ago, in fall of 1995, the first WUFI®-Seminar was held in Holzkirchen, Germany. By that time the selling of WUFI® 1D (nowadays WUFI® Pro) started. We want to celebrate this anniversary by giving you 20% discount on all WUFI® software and all WUFI® upgrades within the next two months.
The campaign runs between October 15 and December 15, 2015.
During the campaign, the upgrade of WUFI® Pro 5.3 to WUFI® Pro 6.0 will be included in the new purchase price of 2300€. You will be informed via E-Mail as soon as the upgrade is available (expected release at the end of November 2015).
For further information, please visit the online shop from October 15 onwards.

Contine reading

Two-dimensional test cases of ISO 10211

WUFI® 2D computes the time-dependent temperature and moisture fields in a two-dimensional cross-section of a building component. Such a two-dimensional computation automatically includes so-called geometrical and structural thermal bridge effects. These are the effects which the component shape (e.g. a corner) and variations of the thermal properties within the component (e.g. reinforcement bars) have on the resulting temperature field. The modifications of the temperature field and the associated heat flows by thermal bridges may have important consequences for energy loss, mold growth in damp corners etc.

WUFI® 2D is not intended to compete with dedicated thermal bridge programs which usually offer more flexible modelling interfaces and provide specific thermal bridge properties. But it can investigate the effect of thermal bridges on energy losses and, in particular, on the hygric conditions in and on building components (mold growth, damage due to condensation etc.), which purely thermal programs can not.

The international standard ISO 10211 provides a series of two- and three-dimensional test cases for validating thermal bridge software. Of course, WUFI® 2D should be able to reproduce the two-dimensional test cases.

 

Test case 1

WUFI-2D_Benchmarktest1

Case 1 considers one half of a symmetrical square column with known constant surface temperatures. The steady-state temperature distribution over the cross-section can be computed analytically. 28 temperatures on an equidistant grid are given by the standard as the reference solution; the software to be validated must reproduce these temperatures within 0.1° C.

 

500x308_WUFI-2D-Benchmark1The given boundary conditions (20° C along the top edge, 0° C along the left and bottom edges, and adiabatic along the right edge) result in a temperature field with strong variation close to the upper left corner and little variation towards the bottom of the cross-section.
Usually, one would therefore create a more efficient variable-size computational grid with fine grid elements close to the upper left corner and progressively larger grid elements towards the bottom. However, since for the present purpose the temperatures must be evaluated at precisely given coordinates and WUFI® computes the temperatures for the centers of the grid elements, a grid has to be created which ensures that a small element is centered at each of the requested positions.
To this end, the monolithic component has been built up from 28 separate blocks which fill up the space between the reference points and are subdivided by relatively coarse grids. The blocks are separated by 4 mm wide gaps which are subdivided by very fine grids in such a way that one small grid element is precisely centered on each reference point (one at each intersection of the gaps).

Since in the present case of a monolithic component with given surface temperatures the steady-state solution for the temperature field does not depend on the thermal properties, any arbitrary material data may be used. The data of concrete were chosen for this exercise.

The prescribed surface temperatures are applied to the component by setting the ambient air to the desired temperatures and the heat transfer coefficients for the surfaces to very large values. For the adiabatic right-hand surface (the symmetry plane which allows to limit the calculation to one half of the original square column), the heat transfer coefficient has been set to zero in order to suppress any heat exchange.

WUFI® 2D has no mode for steady-state solutions, but such a solution is approached to arbitrary precision if a transient computation with constant boundary conditions is performed for a sufficient number of time steps. Here, 10 steps of 48 hours each were found to be sufficient. Moisture transport was switched off for this purely thermal computation.

A graphical postprocessor for the calculation results allows to extract the final temperatures from any grid element. The comparison with the reference temperatures shows that WUFI’s temperatures deviate by 0.05° C or less and are thus well within the allowed deviation of 0.1° C.

You can download a WUFI® 2D project file (65 KB) for the benchmark calculation. Use the “Import…” function of WUFI® 2D to read this compressed archive file.

 

Test case 2

WUFI-2D_Benchmarktest3

WUFI-2D_Benchmarktest4

Case 2 considers the heat flow through a building component which contains materials with widely differing thermal conductivities.

Dimensions (mm):
AB= 500 CD = 15 EM = 40 IM = 1.5
AC = 6 CF = 5 GJ = 1.5 FG-KJ = 1.5

 

Thermal conductivities (W/mK):
1 (concrete): 1.15 2 (wood): 0.12 3 (insulation): 0.029 4 (aluminum): 230

 

Boundary conditions:
AB: 0° C with Rse = 0.06 m²K/W HI: 20° C with Rsi = 0.11 m²K/W

The prescribed building component can easily be assembled from rectangles, using WUFI’s graphical component editor. The automatically generated grid with the fineness setting “coarse” is sufficient for this computation.

The thermal conductivities for the four involved materials are specified by the standard and have been entered in WUFI® accordingly. Since WUFI® needs a full set of thermal porperties for each material (including heat capacity etc.) the missing data have been taken from similar materials in WUFI’s material database. The steady-state result only depends on the prescribed thermal conductivities, not on the added properties.

The ambient air temperatures and the heat transfer coefficients for the top and bottom surfaces are entered in WUFI® 2D as specified by the standard. The left and right surfaces are treated as adiabatic by setting the respective heat transfer coefficients to zero.

In this case, too, the steady-state solution must be approximated by a transient calculation with constant boundary conditions. 30 steps of one hour each were found sufficient.

500x173_WUFI-2D-Benchmark2

The resulting temperatures at the specified locations can again be extracted with the graphical postprocessor. However, the standard asks for temperatures on material boundaries whereas WUFI® computes the temperatures for the centers of the grid elements and any material boundaries must always coincide with boundaries between grid elements. So in this case it is not possible to center grid elements on the requested locations (such grid elements would contain two or more different materials which is not allowed).

Close to the four corners (points A, B, H and I), the temperature variation is so small that the center of the outermost grid element instead of the true geometric corner can be taken as sufficiently representative.

Where the requested location lies between two materials (points C, E and F), the temperature at this location must be computed from the temperatures at the centers of the two grid elements straddling the location. The temperature ϑm for a location m between locations 1 and 2 can be computed by ϑm = ((λ1/s1) ϑ1 + (λ2/s2) ϑ2) / ((λ1/s1)+(λ2/s2)), where ϑi is the temperature at location i, λi is the thermal conductivity between locations i and m, and si is the distance between locations i and m. Since the grid elements straddling a material boundary all have the same size, the si cancel and the expression reduces to ϑm = (λ1 ϑ1 + λ2 ϑ2) / (λ12).

For locations where three materials meet (points D and G), the temperature has been computed from the temperatures in the four adjacent grid elements by the following generalisation of the above formula: ϑm = (λ1 ϑ1 + λ2 ϑ2 + λ3 ϑ3 + λ4 ϑ4) / (λ1 + λ2 + λ3 + λ4).

The comparison with the reference temperatures shows that WUFI’s temperatures deviate by 0.1° C or less and are thus within the allowed deviation of 0.1° C. The heat flow through the component is 9.5 W/m and thus within the required (9.5 ± 0.1) W/m.

You can download a WUFI 2D project file (30 KB) for the benchmark calculation. Use the “Import…” function of WUFI® 2D to read this compressed archive file.

 

 

Last Update: April 22, 2024 at 15:45

Benchmark test of EN 15026

European standard EN 15026 provides minimum criteria for simulation software used to predict one-dimensional transient heat and moisture transfer in multi-layer building components exposed to transient climate conditions on both sides.

The standard lists model equations and pertinent material properties which shall be used for computing heat and moisture transport phenomena. These model equations allow for the following storage and transport phenomena:

  • heat storage by the dry materials and the absorbed water,
  • heat transport by moisture-dependent thermal conduction,
  • latent heat transfer by vapor diffusion,
  • moisture storage by vapor sorption and capillary forces,
  • moisture transport by vapor diffusion,
  • moisture transport by liquid transport (surface diffusion and capillary flow),

and the following boundary conditions:

  • indoor and outdoor temperature,
  • indoor and outdoor humidity,
  • solar and long-wave radiation,
  • precipitation (normal and driving rain),
  • wind speed and direction.

Furthermore, the standard adopts several simplifying assumptions; for example, swelling and shrinking processes, chemical reactions and ageing processes are ignored, the moisture storage function is treated as independent of temperature, etc.

WUFI® complies with all requirements of standard EN 15026.

Benchmark Example

Standard EN 15026 defines a benchmark example for validating hygrothermal simulation software. It is designed to ensure that the software meets some basic requirements and produces results which are correct within a specified tolerance. The example considers the heat and moisture absorption of a semi-infinite slab of material which initially is in equilibrium with the boundary conditions ϑ = 20°C, φ = 50% and then is subjected to the new conditions ϑ = 30°C, φ = 95%.

The sudden increase of the temperature and moisture content at the surface causes heat and moisture to flow into the material. The temperature and moisture profiles resulting after 7, 30 and 365 days are to be calculated. The results of the software under test must not deviate from the reference solution by more than 2.5 %.

WUFI’s results for the benchmark example are virtually identical with the reference solution (see diagrams), it therefore complies with the requirements established by EN 15026.

You can download a WUFI Pro project file (WUFI® Pro 4 (25kB), WUFI® Pro 5 (11kB) oder WUFI® Pro 6 (11kB)) for the benchmark calculation. An accompanying PDF file (513 KB) states WUFI’s compliance with EN 15026 and documents how the benchmark specifications have been translated for use with WUFI® .

500x308_WUFI-Pro-Benchmark1 500x308_WUFI-Pro-Benchmark2

 

Last Update: April 22, 2024 at 15:45

Assessment of mold growth risk

Assessment of mold growth riskUnder unfavorable ambient conditions, microbial growth may occur on the surfaces of building components. The most important factors are temperature, relative humidity, a substrate with sufficient nutrients and the daily duration of the period where all growth conditions prevail simultaneously (coincidence time). While bacteria need relative humidities of at least 90% for being able to grow, certain xerophilic fungi can thrive at humidities as low as 65%, and most fungi can cope with humidities as low as 80%. Mold fungi also tolerate a larger temperature bandwidth than other organisms, they may grow between 0°C and 50°C. Therefore the whole range of humidities and temperatures mentioned above may be considered to pose a potential mold growth risk.

Fig. 1 shows a qualitative assessment of the growth conditions for mold in dependence of the above factors. These functional relationships served as the basis for a prediction method for assessing the mold growth risk which has already been applied repeatedly and has been validated by comparison with experiment [1]. The input data are the local temperature and humidity conditions resulting from a non-steady simulation. The influence factors are combined by fuzzy logic which allows for the natural uncertainty inherent in specifying e.g. the humidity interval favorable for growth. The output of the assessment is a measure for the amount of mold growth to be expected. Current work is aimed at extending the above non-steady method to create an encompassing safety concept as has been called for and developed in a steady-state version by [2].

Literature

Sedlbauer, K.; Oswald, D.; König, N.: Schimmelgefahr bei offenen Luftkreisläufen. Vorstellung einer Prognosemethode auf der Basis von Fuzzy-Algorithmen. Gesundheits-Ingenieur, Heft 5 (1998), S. 240 – 247.
Cziesielski, E.: Schimmelpilz – ein komplexes Thema. Wo liegen die Fehler? wksb 44 (1999), H. 43, S. 25 – 28.

 

Page created: 14 May 2007; last update: 17 Jul 2012

Retrofitting Interior Insulation to a Pitched Roof

Retrofitting Interior Insulation to a Pitched RoofConverting attic space into living space becomes increasingly popular. Since the unvented type of insulation is energetically more favorable and since this type is easier to install if the insulation has to be added to an existing roof, it should be preferred over a vented variant, unless possible moisture problems are a concern. Since older pitched roofs usually have a relatively vapor-tight exterior lining (e.g. bituminous roofing felt on wood sheathing) they require an analysis of possible condensation problems. German standard DIN 4108-3 dispenses with calculational approval if the room-side vapor barrier has a very high vapor resistance (sd-value > 100 m). However, because such constructions which are then vapor-tight on both sides run a considerable risk of severe moisture damage if small defects or leaks occur, it is advisable not to follow the standard here as was already correctly pointed out in [1]. It has also been recommended there to use vapor retarders instead whose diffusion resistance has been selected to limit condensation in winter to an uncritical level while some drying of moisture that has infiltrated in the component is allowed in summer.

This is a typical optimization problem which clearly demonstrates the advantages of computational simulation. If the traditional Glaser method is used for this, a minimum sd-value of about 2 m is found. However, the Glaser method only approves the construction if the prescribed boundary conditions for roofs are used (surface temperature 20 °C). If the boundary conditions for walls are used, then the amount of condensing moisture usually exceeds the amount of evaporating moisture and the construction fails the Glaser test. Whether a high-pitched roof facing north can be assessed more realistically using the boundary conditions for flat roofs exposed to sunshine or boundary conditions for walls is left to the judgement of the person in charge. In the following it will be shown which insight can be gained with WUFI calculations.

The effect of different boundary conditions and diffusion properties of the vapor retarder on the moisture situation in the north-facing half of an unvented double-pitch roof (inclination 50°) with vapor-tight exterior lining and insulation applied between the rafters has been investigated by computational simulation (see [2]). Fig 1 shows the evolution in time of the total moisture content in this roof for three different sd-values of the vapor retarder, assuming normal indoor moisture load, exterior climate conditions typical for Holzkirchen and an initial hygroscopic equilibrium moisture corresponding to 80% RH. If the vapor retarder has an sd-value of 0.5 m, the roof absorbs about 1.5 kg/m² of moisture from the indoor air in winter and completely releases it during the next summer, with the total water content at the end of the evaluation period of six years corresponding approximately to the initial water content. However, the high moisture accumulation in winter exceeds the limit for maximum condensation set by standard DIN 4108 and cannot be tolerated because the condensation moisture might collect and run off. If the sd-value of the vapor retarder is increased by a factor of ten, the moisture increase remains well below the critical limit of 0,5 kg/m². But now the moisture accumulates in the long term, as evidenced by the slow year-by-year increase of the computed moisture contents. A possible solution for this situation is a vapor retarder with variable sd-value, whose moisture-adaptive properties make it more vapor-tight in winter than in summer. Such a vapor retarder combines a low moisture increase by condensation in winter with a high drying potential in summer, so that the moisture content at the end of the evaluation period is even lower than in the other cases.

Specifications devised by extensive WUFI calculations were used to guide the development of this unique vapor retarder, providing another example for successful application of hygrothermal simulations to the development and optimization of building products [3].

 

Literature

Schulze, H.: Hausdächer in Holzbauart. Werner-Verlag, Düsseldorf 1987.
Künzel, H.M.: Bedeutung von Klimabedingungen und Diffusionseigenschaften für die Feuchtesicherheit voll gedämmter Altbaudächer. Festschrift zum 60. Geburtstag von Prof. Gertis. Fraunhofer IRB Verlag, Stuttgart 1998, S.371-389.
Künzel, H.M. und Kasper, F.-J.: Von der Idee einer feuchteadaptiven Dampfbremse bis zur Markteinführung. Bauphysik 20 (1998), H.6, S.257-260.

 

Page created: 10 May 2007; last update: 17 Jul 2012